Москва - (495) 204-28-08
Санкт-Петербург - (812) 424-56-18
Екатеринбург - (343) 216-9-777
Email: incoll@rs-catalog.ru

RS PRO Type T Thermocouple 3m Length, 1/0.2mm Diameter, -75°C → +260°C

2209488
Производитель: RS PRO
Цена за шт.
4691.70 руб. (С НДС) *

Срок поставки: 4-6 недель

+

* УТОЧНЯЙТЕ ВОЗМОЖНОСТЬ, ЦЕНУ И СРОК ПОСТАВКИ, В СВЯЗИ С ОГРАНИЧЕНИЕМ ЭКСПОРТА ТОВАРОВ ИЗ СТРАН ЕС И ВЕЛИКОБРИТАНИИ

RS PRO IEC Type J, K & Type T Exposed Welded Tip Thermocouple and Miniature Plug

Introducing the range of RS PRO Type J, K and Type T fine wire temperature sensing thermocouples that conform to IEC-584-3 standards with a Class 1 tolerance for optimum performance. These Type K and Type T fine wire temperature sensors have a durable Teflon PTFE insulated class 1 twin-twisted 1/0.2 mm lead. The lead is terminated with a rewireable miniature flat pin plug for a quick and easy connection. These thermocouples have an exposed welded junction which enables them to operate with a fast response time.

Features and Benefits:

  • IEC-584-3 class 1 tolerance for optimum accuracy

  • Miniature plug for quick and easy connection

  • Exposed welded junction for fast response

  • Durable Teflon PTFE insulation for resistance to oils, acids and fluids and good mechanical strength and flexibility

  • Temperature range from -75 to +250°C

Applications:

These Type J, K and Type T fine wire thermocouple temperature sensors are ideal for test and development applications including:

  • Test and measurement

  • Temperature mapping

  • OEM applications

How does a Thermocouple Work?

A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables which is a process also known as the Seebeck Effect.

What is a Welded Exposed Junction?

An exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Why RS PRO?

RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards they’re only given the RS PRO seal of approval if we’re confident of their exceptional quality, which means you can be confident too.

Техническая спецификация
pdfRS PRO Datasheet
pdfRS PRO Datasheet
Диаметр зонда:
1/0.2мм
Длина зонда:
Кабель - длина:
Максимальная температура зондирования:
+260°C
Материал щупа:
Teflon PTFE
Минимальная температура зондирования:
-75°C
Тип выводов:
Twin Twisted Tail
Тип термопары:
T
Самовывоз со склада поставщика в Екатеринбурге Забираете сами или вызываете курьера
ТК Деловые Линии от 500 руб
Курьером EMS Почта России от 500 руб
Другой транспортной компанией По согласованию