ESP 240-16A, WJ Furse ESP 240 Series 280 V Maximum Voltage Rating 10kA Maximum Surge Current Low Current Mains Protector, DIN Rail

4568140
Номер производителя: ESP 240-16AПроизводитель: WJ Furse
Цена за шт.
59706.00 руб. (С НДС) *
Количество 5+ 10+ 20+
Цена 57318.00 руб. 54330.00 руб. 49554.00 руб.

Срок поставки: 4-6 недель

+

* УТОЧНЯЙТЕ ВОЗМОЖНОСТЬ, ЦЕНУ И СРОК ПОСТАВКИ, В СВЯЗИ С ОГРАНИЧЕНИЕМ ЭКСПОРТА ТОВАРОВ ИЗ СТРАН ЕС И ВЕЛИКОБРИТАНИИ

Overvoltage Protectors for Low Current Mains Supplies

Over Voltage protectors for low current mains power supplies to protect electronic equipment e.g. CCTV cameras, alarm panels and telemetry equipment.

Very low let-through voltage between all lines (L-E, L-N, N-E)
Sturdy housing with M6 earth stud
Removable DIN rail foot for easy installation (unboxed versions). Can also be flat-mounted.
IP66 rated boxed version (/BX parts)
Colour-coded terminals

Weatherproof Enclosures

Tough polycarbonate enclosures

WBX enclosures for ESP protectors provide added protection in damp and dirty environments. Ideal for use when the protectors cannot be installed within an existing equipment panel or enclosure.

Approvals

Network Rail approval (ESP 240-5A/BX) – PA05/02896. NRS PADS ref: 087/037285

Transient Voltage Suppressors (Modules,Industrial)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.

Техническая спецификация
pdfESP 5A/BX and 16A/BX Series Data Sheet
pdfProtection for Data and Signal Lines in Intrinsically Safe Circuits Application Note
pdfChoosing the Correct Furse ESP Lightning Barrier for your Application
pdfProtection of Wind Turbines Application Note
pdfProtection of Photovoltaic (PV) Systems Application Note
pdfABB IET Wiring Regulations BS 7671 18TH Edition
Высота:
54мм
Глубина:
38мм
Длина:
120мм
Максимально допустимое напряжение:
280 В
Максимальный ток перенапряжения:
10кА
Рабочая температура - максимальная:
+70°C
Рабочая температура - минимальная:
-40°C
Размеры:
120 x 54 x 38мм
Серия:
ESP 240
Тип монтажа:
DIN Rail
Тип супрессора:
Low Current Mains Protector