XPSCM1144 Schneider Electric Telemecanique Safety Relay Module Safety Light Curtains XUSL.
From Schneider Electric we offer you the Preventa XPS range of Safety relays (safety modules) providing the solution and answer to monitoring safety relay functions. The relays include redundancy principle micro-pressor technology providing you with advanced functionality. There are various safety relay models to choose from, including removeable terminal block versions, allowing easy selection of a module to monitor a safety functions.
Features.
- Emergency stop and switches
- Coded magnetic switches
- Enabling switch
- Sensing mats and edges
- Two-hand control
- Light curtains
- Zero speed
- Time delay
- Lifts
- Other applications on hydraulic and eccentric presses.
- The safety relays are suitable for all applications with hazards and protect machines and operators.
These safety modules can be used in conjunction with the Harmony XY2SB range of two-hand control stations
What Safety Relay should I use with a Two Hand Control Station?
Safety modules XPS BA, BC and BF may be used for two-hand control stations in order to comply with the requirements of European standard EN 574/ISO 13851 for two-hand control systems.
XPSCM1144 Features and Benefits.
- Telemecanique safety module XPSCM.
- For monitoring Single Beam photo electric sensor.
- Built-in muting.
- Inputs – 2 x terminals MA, MB for muting function, 4 x terminals Z1, Z2, Z3, Z4 – for the sensor.
- Input voltage of 24 V dc (sensor), 24 V dc (muting) terminals U+, U-.
- Input capacity - XC limit switch for muting function, XU2M18PP340 for muting function, XU2S18PP340 (infrared) for sensor, XU9M18PP340 for muting function.
- Captive screw clamp terminals.
- 2 NO output, volt free (13-14, 23-24).
- Rated supply voltage 24 V dc.
- Sensor power supply U+, U- / 24 V dc.
- Sensor supply current 200 MA.
- Maximum muting duration of 60 s (-10 – 30%).
- Line resistance 10 Ohm for sensor power supply (maximum).
- Output current 10 MA (relay).
- Output voltage 17 V (relay) minimum.
- 25 Ms response time (maximum) on input open.
- LEDs - 1 LED, function electronic internal fuse status, 1 LED, function restarting, 1 LED, function safety outputs closed, 1 LED, function safety outputs open, 1 incandescent lamp, function muting power consumption: 4 - 6.5 W.
- 15 W Maximum power consumption.
- Electronic internal fuse.
IP Protection.
- IP20 (terminals) conforming to IEC 60529.
- IP40 (enclosure) conforming to IEC 60529.
Safety.
- Can reach category 2 with the appropriate control system and correctly wired conforming to EN/ISO 13849-1.
- Can reach SILCL 1 with the appropriate control system and correctly wired conforming to EN/IEC 62061.
- Can reach PL = c with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
Safety Reliability.
- MTTFd = 16.6 years conforming to EN/ISO 13849-1.
- DC = 95.5 % conforming to EN/ISO 13849-1.
- PFH = 3.12E-7 1/h conforming to EN/IEC 61508.
- PFHd = 3.12E-7 1/h conforming to EN/IEC 62061.
Note
This product is supplied with a full installation instruction manual which should be strictly adhered to. Particular attention should be given to section 3.5 (installation positioning and electrical inter-phasing).
Single Beam Safety Device
Техническая спецификацияManuel d'utilisation XPS-CM
Machine Guarding and Safety Range Overview
Packaging Machines Application Software
Packaging Automation
Datasheet XPSCM1144
Green Premium Ecolabel
Product Environmental Profile
Самовывоз со склада поставщика в Екатеринбурге | Забираете сами или вызываете курьера |
ТК Деловые Линии | от 500 руб |
Курьером EMS Почта России | от 500 руб |
Другой транспортной компанией | По согласованию |