* УТОЧНЯЙТЕ ВОЗМОЖНОСТЬ, ЦЕНУ И СРОК ПОСТАВКИ, В СВЯЗИ С ОГРАНИЧЕНИЕМ ЭКСПОРТА ТОВАРОВ ИЗ СТРАН ЕС И ВЕЛИКОБРИТАНИИ
USB DrDAQ® 2011 Data Logging Kit - PP707
While the USB DrDAQ DrDAQ data logger unit (RS 749-1914) comes with many built-in sensors, the USB DrDAQ Data Logging Kit PP707 (RS 749-1917) contains additional sensors and probes to enable many other measurments to be taken, therefore allowing further experiments to take place immediately.
Supplied with
USB DrDAQ data logger board
pH electrode
Dr DAQ 2metre temperature sensors
DrDAQ humidity sensor
Software CD
USB Installation Guide
3m sensor extension cable
Scope probe x1 / x10 switchable
USB2 cable, 1.8 metre, blue
Dr DAQ represents a breakthrough in data logging. Simply plug Dr DAQ into the parallel port of any PC, run the supplied software and you are ready to collect and display data. Everything required is supplied: Dr DAQ uses power from the PC so no batteries are required. Dr DAQ is an ideal tool for engineers or can be at the heart of hundreds of educational science experiments.
As well as the built-in sensors, Dr DAQ has two sockets for external sensors. When a sensor is plugged in to Dr DAQ the software detects it and automatically scales readings. For example if a temperature sensor is plugged in readings are displayed in °C. Details are provided to allow users to develop their own sensors.
Very low cost data logger
On board sensors for light, sound and temperature
ISKS/s enables Dr DAQ to capture fast signals (e.g. sound waveforms)
Built-in sensors for light, sound and temperature
Sockets for external sensors
Measures pH - just plug in any standard electrode
Output for control experiments
Simply plug into your PC and measure. PicoLog (data logging) and PicoScope (oscilloscope and spectrum analyser) software included
Dr DAQ Built-in Sensors
Temperature is sensed using a precision Thermistor. It can measure over the range 0 to 70°C with a resolution of 0.1°C (at 25°C)
The light sensor is designed for measuring ambient light levels. It has a fast response so can also be used to measure the flicker of lights or computer monitors
The internal microphone measures both sound level and sound waveforms. Sound level is 'A law' weighted to match the response of the human ear and can be measured over the range 55 to 100dBA. Sound waveforms can be displayed in both the time (oscilloscope) and frequency (spectrum analyser) domain
Voltage (0 to 5V) and Resistance (0 to 1MΩ) can be measured using the screw terminal connectors
A digital output and a LED are also provided for control/alarm purposes. These can be set on/off using threshold limits on any channel
USB DrDAQ Data Sheet
USB DrDAQ Data Logger Users Guide
Самовывоз со склада поставщика в Екатеринбурге | Забираете сами или вызываете курьера |
ТК Деловые Линии | от 500 руб |
Курьером EMS Почта России | от 500 руб |
Другой транспортной компанией | По согласованию |