Москва - (495) 204-28-08
Санкт-Петербург - (812) 424-56-18
Екатеринбург - (343) 216-9-777
Email: incoll@rs-catalog.ru

CN200A110-12, TDK-Lambda CN-A DC-DC Converter, 12V dc/ 16.7A Output, 60 → 160 V dc Input, 200.4W, Through Hole, +100°C Max, Преобразователь

7649302
Номер производителя: CN200A110-12Производитель: TDK-Lambda
Цена за шт.
62411.70 руб. (С НДС) *

Срок поставки: 4-6 недель

+

* УТОЧНЯЙТЕ ВОЗМОЖНОСТЬ, ЦЕНУ И СРОК ПОСТАВКИ, В СВЯЗИ С ОГРАНИЧЕНИЕМ ЭКСПОРТА ТОВАРОВ ИЗ СТРАН ЕС И ВЕЛИКОБРИТАНИИ

TDK Lambda CN-A Series, 30W to 200W 110VDC Input, Quarter Brick & Half Brick Railway Isolated DC-DC Converter

CN-A series, 30 to 200W 24Vdc input, railway isolated DC-DC converters with a compact quarter brick and half brick design (CN30A - 100A: 36.8 x 12.7 x 57.9mm, CN200A: 61 x 12.7 x 57.9mm) that uses less PCB space, a wide input voltage range of 60 to 160 Vdc and full regulation. These 30 to 200W railway isolated DC-DC converters are compliant with the applicable railway standards and are designed for harsh environments, meeting the shock and vibration requirements of IEC61373 Category 1 Class B. A true useable power from -40 to +100°C without derating can be provided by these railway isolated DC-DC converters which are base-plate cooled, they can also offer up to 88% efficiency and up to 4.2A useable output current. Typical uses for these railway isolated DC-DC power modules include battery powered railway systems such as rolling stock and fixed installations, power plants and customer power supplies.

Wide 60 - 160Vdc Input to EN50155/IEC60571
Compliant with applicable railway standards
Shock and vibration compliant to IEC61373 Category 1 Class B
Full power from -40˚C to +100˚C without derating (covers TX class for Railway)
Base plate cooled
High efficiency of up to 88%
Up to 4.2A useable output current
3kVac input/output isolation
Remote sensing and remote on/off functions
Overvoltage and overcurrent protection
Undervoltage lockout function (UVLO)
Protects battery against deep discharges
Compact size: CN30A - 100A: 36.8 x 12.7 x 57.9mm, CN200A: 61 x 12.7 x 57.9mm

Standards

UL60950-1, CSA60950-1, EN60950-1, CE LVD

TDK Lambda 100 to 200W Railway Isolated DC-DC Converters

Техническая спецификация
pdfCN-A_EN_datasheet
Выходной ток:
16.7A
Глубина:
12.7мм
Диапазон входного напряжения:
60 → 160 В пост. тока
Длина:
57.9мм
Изолировано:
Да
Количество выходов:
1
Максимальная температура:
+100°C
Минимальная температура:
-40°C
Мощность номинальная:
200.4Вт
Напряжение выходное:
12В пост. тока
Напряжение изоляции:
3кВ перем. тока
Номинальное входное напряжение:
110 В пост. тока
Регулирование нагрузки:
96мВ
Серия:
CN-A
Тип монтажа:
Сквозное отверстие
Упаковка:
1/2 Brick
Эффективность:
88%
Самовывоз со склада поставщика в Екатеринбурге Забираете сами или вызываете курьера
ТК Деловые Линии от 500 руб
Курьером EMS Почта России от 500 руб
Другой транспортной компанией По согласованию