Москва - (495) 204-28-08
Санкт-Петербург - (812) 424-56-18
Екатеринбург - (343) 216-9-777
Email: incoll@rs-catalog.ru

2807586, Phoenix Contact, VAL-MS 120 ST Surge Protector 120 V ac Maximum Voltage Rating 40kA Maximum Surge Current Surge

8026684
Номер производителя: 2807586Производитель: Phoenix Contact
Цена за шт.
37502.40 руб. (С НДС) *

Срок поставки: 4-6 недель

+

* УТОЧНЯЙТЕ ВОЗМОЖНОСТЬ, ЦЕНУ И СРОК ПОСТАВКИ, В СВЯЗИ С ОГРАНИЧЕНИЕМ ЭКСПОРТА ТОВАРОВ ИЗ СТРАН ЕС И ВЕЛИКОБРИТАНИИ

VALVETRAB® Pluggable single-pole modular lightning surge protector

The 2798844 from Phoenix Contact is a type 2 surge protection plug. This plug is designed to protect low voltage or three phase power supplies in your installations. It's backed with thermal monitoring, easy pluggable design that’s allow for simple maintenance, mechanical indicator that shows the status and a wiring bridge that allows multiple modules to easily connect and be bridged on the ground connection. VALVETRAB provides L-N and L-PEN protection.

Features and benefits:

  • Type 2 with high-capacity varistor for VAL-MS based element

  • For TN/TT systems

  • 230V power supply units according to DIN VDE 0100-534

  • Display to show if the device has an error or damaged

  • Connects in parallel on the mains network and snaps onto a symmetric profile

Accessories:

e 2 base element - 445-5252, 220-3627

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Техническая спецификация
pdfType 2 surge protection plug - VAL-MS 120 ST
Высота:
55.3мм
Глубина:
17.5мм
Длина:
52.4мм
Максимально допустимое напряжение:
120 В перем. тока
Максимальный ток перенапряжения:
40кА
Рабочая температура - максимальная:
+80°C
Рабочая температура - минимальная:
-40°C
Размеры:
52.4 x 17.5 x 55.3мм
Серия:
VAL-MS 120 ST
Тип монтажа:
DIN Rail
Тип супрессора:
Surge Arrester Protection Module
Самовывоз со склада поставщика в Екатеринбурге Забираете сами или вызываете курьера
ТК Деловые Линии от 500 руб
Курьером EMS Почта России от 500 руб
Другой транспортной компанией По согласованию