102102 & FAZ-D4/1-NA, Eaton xEffect 4A MCB Mini Circuit Breaker, 1P Curve D

9226936
Номер производителя: 102102 & FAZ-D4/1-NAПроизводитель: Eaton
Цена за шт.
23082.00 руб. (С НДС) *

Срок поставки: 4-6 недель

+

* УТОЧНЯЙТЕ ВОЗМОЖНОСТЬ, ЦЕНУ И СРОК ПОСТАВКИ, В СВЯЗИ С ОГРАНИЧЕНИЕМ ЭКСПОРТА ТОВАРОВ ИЗ СТРАН ЕС И ВЕЛИКОБРИТАНИИ

Eaton FAZ Series MCBs

Eaton FAZ- miniature circuit breakers are Current limiting design provides fast short-circuit interruption that reduces the let-through energy that can damage the circuit, Trip-free design. Breaker cannot be defeated by holding the handle in the ON position

Features and Benefits

Thermal-magnetic overcurrent protection
Power to the circuit breakers can be fed from the line or load side
Clear indication of contact position via front switch toggle
Easy installation on DIN rail. Module width of only 17.5 mm (per pole)
Six levels of short-circuit protection, categorized by B, C, D, K, S and Z curves
Small modular width of the device and accessories saves space in the panel or equipment, which can lead to cost savings
Dual rated for IEC 60947-2 standard
Module widths: 1 Pole 17.5mm, 2 pole 35mm and 3 pole 52.5mm

Standards

IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s) and also air circuit breakers (ACB’s).

Q: What is the differences in the Tripping Curves B, C, D and S?

A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Curve S Tripping 13 to 17 times the rated current
Suitable for applications where high levels of inrush current are expected. Instantaneous trip is 13–17X rating of device (In). The high magnetic trip point prevents nuisance tripping in high inductive applications such as motors, transformers and power supplies

Standards

IEC 898; BS/EN60-898; EN50 022/DIN46277-3 (BS5584).
FAZ-C*/* & FAZ-S*/* = IEC/EN60947-2

Техническая спецификация
pdfFAZ Series
Глубина:
80мм
Диапазон:
xEffect
Длина:
17.8мм
Количество полюсов:
1
Номинал тока:
4A
Номинальное напряжение переменного тока:
240 → 415V
Номинальное напряжение постоянного тока:
48В
Отключающая способность при максимально допустимом напряжении:
10 кА
Перерыв:
Мгновенный
Размыкающий механизм:
Thermal-Magnetic
Серия:
FAZ
Тип автоматического выключателя:
MCB
Тип контактов терминала:
Винт
Тип сбрасываемого привода:
Перекидной выключатель
Характеристики срабатывания:
Type D
Ширина:
65.5мм
Самовывоз со склада поставщика в Екатеринбурге Забираете сами или вызываете курьера
ТК Деловые Линии от 500 руб
Курьером EMS Почта России от 500 руб